Sign In | Join Free | My burrillandco.com
Home > UV Visible Spectrophotometer >

Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer

PEAK Instruments (Shanghai) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers
     
    Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers
    • Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers
    • Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers
    • Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers
    • Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers
    • Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers
    • Buy cheap Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer from wholesalers

    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer

    Ask Lasest Price
    Brand Name : PEAK INSTRUMENTS
    Model Number : C7200
    Price : $2,850.00/units 1-4 units
    • Product Details
    • Company Profile

    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer

    Product Description
    Product Name
    Double beam 190-1100nm UV Visible 2nm Spectrophotometer
    Origin
    China
    Brand
    PEAK INSTRUMENTS
    Model
    C7200
    Functions
    Photometry, quantitative measurement, kinetics, multiwavelength test, wavelength scanning, DNA/Protein test on standalone device
    PC Software
    Optional
    Size
    61*46*24CM
    Weight
    23KG
    Wavelength range
    190-1100nm
    Display
    7 inch LCD screen
    Optical System
    Double beam, Holographic Grating (1200 Lines/mm)
    Spectral Bandwidth
    2nm
    Wavelength Accuracy
    ±0.3nm
    Wavelength Repeatability
    ≤0.2nm
    Stray Light
    ≤0.05%T@220, 360nm
    Baseline Flatness
    ±0.002A
    Noise
    0.0003@500nm
    Detector
    Solid Silicon Photodiode
    Data Export
    USB(A) for date transfer, USB(B) for PC software, RS232 for optional printer
    Light Source
    Deuterium/Tungsten Lamp
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    1. Photometry Measurements
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    2. Quantitative Test
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    3. Kinetics Measurement(time scanning)
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    4. Wavelength Scanning
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    5. Multiwavelength Test
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    6. DNA/Protein Measurement
    Our Advantages
    Quality
    1. Our products have good quality and very positive reputations in the market.
    2. Customers are very happy with them and have a lot of good comments about our intruments and service.
    Delivery Time
    1. We can get them ready 3-5 days after order confirmation for small orders.
    2. For big quantities, need to be confirmed.
    3. In most cases, fast delivery is guaranteed.
    Technical Support
    1. We have service manual. If not, detailed documents or videos will be provided.
    2. We can provide online or site training in our factory.
    3. We can have video conference at any time.
    Aftersales Support
    1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
    2. Within warranty, we will solve the problem for you with no charge(except for consumables).
    3. You can call, text or email us at any time. We have good English speakers.
    Warranty Time
    One year and extendable
    Our product advantages are as follws:
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    1. 7 inch color LCD screen(button models) can show more parameters
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    2. Silicone buttons with much longer life span and easier to be operated
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    3. 7 inch capacitive touch screen and user friendly interface
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    4. Standard USB ports for data transfer and PC software connection.
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    5. More functions for basic models
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    6. Stable system with microcomputer processing
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    7. Automatic 8 position 1 cm cell holder(optional)
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    8. Long path cell holder can holde 1-10cm cuvettes(optional)
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    9. Tube rack for tubes with 16mm diameters(optional for all models)
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    10. Film holder(optional for all models)
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    11. Automatic sampler/sipper system(optional)
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    12. PC software, thermal printer, etc.
    Why Choose Us
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    1. Positive comments from our Italian client
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    2. Good review from our customer in Italy
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    3. Great comments from Syria client
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    4. UAE customer is satified with our pH meter
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    5. Argentina customer is happy with our pH meters
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    6. Turkey user is satisfied with its performance of spectrophotometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    7. Spain customer is very happy with our fast service and professional technical support
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    8. Indian client is happy with our great support
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    9. Peru customer likes our spectrophotometer very much
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    10. Salvador customer has good comments on our pH meter
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    12. Customer in Poland said our products are very good
    Certifications
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer

    CE

    ISO 9001 and ISO14001 are also available
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer

    CE ANNEX

    Product process
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    1.Install main board
    2.Connect the cables for main board
    3.Install W1 lamp and D2 lamp
    4.Assemble sample chamber and cell holder
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    5.Install power board
    6.Assemble monochromator
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    7.Upload software
    8.Adjust and test W1 lamp and D2 lamp
    9.System test
    10.Housing installation and final calibration
    Customer Photos
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Customer visit and training
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Visit cutomers and have a training
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Customer from Brazil
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Visit and train customers in Chile
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Training
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Customer from Argentina
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Clients from Korea
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Distributor from Thailand
    FAQ
    Q: What areas and applications can it be used?
    A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
    Q: Does it need any installation
    A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
    Q: What standard accessories are included?
    A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
    Q: Is PC software included?
    A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
    Q: Why the reading is red and reach its maximum value 3.00Abs?
    A: Probably you use the glass cuvette in UV range.
    Q: Why the wavelength calibration or self checking fail?
    A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
    Q: Why is the reading is not as accurate as before?
    A: Do the wavelength calibration before testing or restore the device to its default factory settings.
    Q: Why PC software can not be installed successfully?
    A: Close your anti-virus software on the computer and do it again.
    Q: Why the software can not be connected successfully?
    A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
    Q: Can the data transferred to USB or PC?
    A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
    Q: Why the Abs value is negative(lower than zero).
    A: Do the blanking or change the reference sample.
    Exhibition
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Analytica in Germany
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Pittcon in USA
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    ArabLab in Dubai
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    IndiaLabExpo in India
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Analytica Lab Africa
    Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer
    Analitica Latin America in Sao Paulo, Brazil
    Quality Wavelength Setting Auto/Resolution 0.1nm Professional Ultraviolet-Visible Spectrometer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: PEAK Instruments (Shanghai) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)